Relighting a Furnace Pilot Light: Troubleshooting a Pilot Light Out

A furnace pilot light going out is a common issue that can disrupt comfort and raise safety concerns in U.S. homes. A pilot light that won’t stay lit may be caused by a dirty thermocouple, a faulty gas valve, drafts, or inconsistent gas supply. This guide explains why pilot lights go out, how to relight safely on older furnaces with standing pilots, and practical steps to prevent future outages. It also covers safety precautions, when to call a professional, and basic cost considerations.

Why The Pilot Light Goes Out In A Gas Furnace

Several factors can cause a furnace pilot light to go out. A flared or flickering flame often signals a worn or dirty thermocouple, which fails to sense heat and shuts off gas to prevent a leak. A defective gas valve or regulator can interrupt the gas flow, while a closed shutoff valve or low gas pressure prevents a stable flame. Dirty pilot assemblies or clogged burners can also extinguish the flame, as can poor venting that creates a backdraft. Finally, drafts near the furnace or aging equipment can spontaneously extinguish a pilot flame.

  • Thermocouple wear or misalignment: Replaces or realigns to restore flame sensing.
  • Gas valve or regulator issues: May require professional inspection or replacement.
  • Gas supply problems: Ensure shutoff valves are open and there is adequate pressure.
  • Dirty pilot orifice or burner: Cleaning or servicing is often needed.
  • Blocked or poorly vented exhaust can extinguish the flame.

Older furnaces are more susceptible to these issues, and regular inspections help catch problems before a total outage occurs. If a smell of gas is detected, or if a CO detector alarms, evacuate the area and call the gas company or emergency services immediately.

Safety First When Your Pilot Light Goes Out

Safety is the top priority when addressing a pilot light outage. A pilot flame that won’t stay lit can hide gas leaks or carbon monoxide buildup, both of which pose serious health risks. Never attempt to relight a pilot if you smell gas or hear hissing sounds around the furnace. Always ensure there is adequate ventilation and use a long lighter to keep hands away from the gas outlet. Keep flammable materials away from the furnace area and maintain clear space for proper combustion and airflow. Install and maintain working CO detectors on every level of the home.

  • Do not relight if gas is present: Evacuate and contact the gas supplier.
  • Use proper lighting tools: Prefer a long-reach lighter or a matchbook-sized lighter with a long handle.
  • Ventilation matters: Ensure vents and exhaust paths are clear.

If you are ever unsure, or if the furnace is older or damaged, contact a licensed HVAC technician to diagnose and repair the system safely. A professional inspection helps prevent recurring outages and ensures safe operation.

Need HVAC Help? Talk to a Pro Today
Free quote over the phone · No-obligation pricing · Service available in many areas
Call 877-693-2753

How To Relight A Standing Pilot Light

Relighting a standing pilot light is a process unique to furnaces that use a persistent pilot flame. Modern furnaces may use an electronic ignition and do not have a standing pilot. Always consult the owner’s manual for model-specific instructions. The steps below describe a typical standing-pilot relight, but do not attempt if you notice gas leaks or persistent ignition failure.

  1. Turn the thermostat to OFF and switch the furnace control to OFF. Wait at least five minutes to clear any accumulated gas.
  2. Locate the gas control knob and set it to OFF, then locate the pilot assembly. If your unit has a safety switch, ensure it is disengaged.
  3. Turn the knob to PILOT. Press and hold the control while lighting the pilot with a long, flame-resistant lighter or a long match.
  4. Hold the flame to the pilot for about 30 seconds after ignition, then slowly release the knob while keeping the pilot lit. If the flame stays lit, turn the control to ON and resume operation.
  5. If the flame goes out as soon as you release the control, repeat the steps once more. If it fails again, turn the gas off, wait longer, and call a professional.
  6. For furnaces with an electronic ignition, follow the manual’s reset procedure or contact a technician. Do not attempt to force a relight where there is an electronic fault.

Additional tips: use a well-lit area, wear safety glasses if handy, and never lean over the flame. If relighting fails repeatedly, or if the flame is weak or irregular, a component like the thermocouple or gas valve may be failing and needs professional replacement.

What If The Pilot Light Keeps Going Out Even After Relighting

If the pilot light continues to go out after relighting, the problem is unlikely to be a simple user error. Common culprits include a faulty thermocouple, a misaligned pilot, or a malfunctioning gas valve. Drafts, improper venting, and restricted combustion air can also cause repeated outages. A persistent outage may indicate gas pressure issues, a blocked vent, or a failing control system. In such cases, it is essential to schedule a professional inspection to diagnose and correct the underlying cause safely.

  • Thermocouple replacement: A worn or bent thermocouple may fail to sense heat and shut off gas.
  • Pilot alignment: Misalignment can prevent reliable ignition.
  • Gas valve or regulator: A faulty valve can intermittently shut off gas supply.
  • Vent and air supply: Blockages or insufficient combustion air disrupt flame stability.

Until a technician arrives, avoid repeatedly trying to relight in quick succession, as this can risk gas buildup or cause damage to components. If you detect a gas leak or strong odor, evacuate and call emergency services immediately.

Maintenance To Prevent A Pilot Light From Going Out

Proactive maintenance reduces the likelihood of a pilot light going out. Regular servicing helps identify wear and tear before it leads to outages. A few practical steps homeowners can take include replacing air filters regularly, ensuring the area around the furnace is clean and free of debris, and keeping vents unblocked. Schedule annual furnace checkups with a licensed HVAC technician to inspect the thermocouple, burner, gas valve, ignition system, and venting. Consider upgrading to an electronic ignition if your system is older and prone to pilot outages, as it typically improves reliability and efficiency.

  • Filter changes: Every 1–3 months, depending on usage and household conditions.
  • Thermocouple inspection: Look for wear, corrosion, or bending; replace if necessary.
  • Vent cleaning: Ensure exhaust paths are clear of obstructions and debris.
  • Gas line safety: Check for leaks and corrosion; have a professional inspect if you notice any odor or hissing.
  • CO safety: Maintain functional CO detectors on every level of the home.

Regular maintenance not only reduces outage frequency but can improve energy efficiency. If you’re considering more modern upgrades, an electronic ignition system can lower standby energy use and provide more reliable ignition, though installation costs vary by furnace model and contractor.

Costs, Efficiency, And When To Consider Replacement

Costs to address a pilot light outage depend on the underlying issue. A simple thermocouple replacement might range from a low hundreds in parts and labor, while a faulty gas valve or regulator could require a more extensive service. If the unit is aging, a full furnace replacement may be more cost-effective in the long term, especially with rising efficiency expectations and modern safety features. On average, homeowners can expect a service call to run from about $100 to $250, with parts and replacements adding to that range depending on the fault.

Energy considerations favor modern furnaces with electronic ignition, which eliminate the continuous pilot flame and reduce idle energy use. If your furnace is over 15 years old and experiences frequent pilot outages, upgrading to a high-efficiency model can improve comfort, safety, and monthly energy costs.

In summary, a pilot light out can often be addressed quickly with proper relighting procedures for standing pilots and proactive maintenance to prevent recurrences. When in doubt, or if gas safety is suspected, contact a licensed HVAC technician promptly to ensure safe and reliable furnace operation.

Cause Possible Fix
Dirty or worn thermocouple Replace or clean; realign sensor
Gas valve/regulator issue Professional inspection and replacement if needed
Backdraft or poor venting Inspect and clear vent; ensure proper drafting
Drafts near furnace Seal openings; improve combustion air
Blocked pilot orifice Clean or replace pilot assembly
Low gas pressure Gas company check; regulator adjustment