Pressure Switch Open Fault on Furnace: Causes, Diagnosis, and Fixes

A pressure switch open fault on a furnace occurs when the safety device that monitors vent pressure does not close as expected. This prevents the burner from igniting, protecting occupants from possible unsafe conditions. The fault is common in high‑efficiency furnaces with induced draft and PVC venting. Understanding how the pressure switch works, what an Open fault signals, and practical steps to diagnose can help homeowners determine whether the issue is resolvable at home or requires a professional service.

What Is A Pressure Switch And What Does Open Fault Mean?

In modern gas furnaces, the pressure switch is a safety component that confirms proper venting pressure as the inducer fan operates. When the inducer starts, it creates a draft that pulls air through the vent and creates a slight vacuum. The pressure switch closes only if the correct draft is detected. An Open fault means the switch has not closed or has failed to maintain continuity, signaling an abnormal venting condition. As a result, the furnace control board halts ignition to prevent potential exposure to combustion byproducts.

Key points include:

  • The switch is typically connected via a small hose to the inducer housing and a pair of wires to the control board.
  • Open readings can occur during cold weather, after a vent blockage, or if a component leaks or fails.
  • Owner checks should focus on venting integrity, inducer operation, and condition of hoses and connections.

Common Causes Of A Pressure Switch Open Fault

Several factors can trigger a pressure switch Open fault. Most are related to venting, cycling components, or wiring. Identifying the root cause helps determine whether the fix is simple maintenance or requires a technician’s intervention.

  • Vent Blockages: Frozen condensate, snow, bird nests, or debris in the PVC vent piping can prevent the correct draft from forming.
  • Inducer Motor Problems: A weak, stuck, or failed inducer motor may fail to create the necessary vacuum for the switch to close.
  • Cracks, disconnections, or collapsed tubing disrupt pressure signals to the switch.
  • A full or clogged condensate trap can back up moisture into the vent system, affecting draft readings.
  • A switch set too high or a faulty switch can fail to close when the inducer runs.
  • Incorrect pipe length, diameter, or pitch can impede airflow and trigger an Open fault.
  • Loose connections, corrosion, or a failing ignition control can mimic or cause a pressure switch fault.
  • In rare cases, cracks or severe corrosion can affect venting dynamics and trigger safety shutoffs.

Safety Considerations

Dealing with a gas furnace involves potential risks, including exposure to carbon monoxide. If there is any smell of gas, hissing sounds, or symptoms of CO exposure (headache, dizziness, nausea), evacuate and call emergency services or the gas supplier immediately. Do not bypass safety switches or run the furnace with a known Open fault. If the home is equipped with CO detectors, ensure they are functioning and have fresh batteries. Regular maintenance and professional inspections are the best defense against dangerous faults.

Need HVAC Help? Talk to a Pro Today
Free quote over the phone · No-obligation pricing · Service available in many areas
Call 877-693-2753

Troubleshooting Steps For A Pressure Switch Open Fault

  1. Power Down And Safety First: Turn off the furnace at the thermostat and switch off the circuit breaker. Do not work on gas lines unless you are trained and certified. Confirm there is no gas odor before proceeding.
  2. Inspect Venting For Blockages: Look for visible obstructions in the PVC exhaust and intake pipes. Clear any snow, debris, or bird nests if present. Ensure vent ends are unobstructed and properly oriented.
  3. Listen for the inducer motor to start smoothly. A grinding, humming, or no sound may indicate a failure or binding that prevents proper draft. Do not attempt repairs beyond basic inspection if unsure.
  4. Inspect all hoses for cracks, kinks, or loose connections. Replace any damaged tubing and reseat fittings firmly on the switch and inducer.
  5. Check the condensate drain and trap for blockages. Clear clogs and ensure the trap is installed correctly. Overflow or backflow can affect vent pressure.
  6. With the power off, you can gently test continuity when the inducer runs, using appropriate electrical testing tools. Do not bypass or bypass safety features. If uncertain, consult a professional.
  7. Reconnect power and set the thermostat to a normal heat cycle. Observe whether the furnace initiates and if the Open fault reappears. If the fault persists, proceed to professional service.

What To Do If The Fault Persists

If basic troubleshooting fails to resolve a Pressure Switch Open Fault, professional service is recommended. A licensed technician can perform diagnostic tests, verify vent integrity, measure draft pressures, and safely replace faulty components. The technician may also check for intermittent electrical faults or control board issues that could trigger the same symptom. Timely intervention can prevent further damage and ensure safe operation.

When To Call A Professional

Call a professional if any of the following apply: the Open fault persists after basic checks, gas odors are detected, there are unusual furnace noises, or there is evidence of moisture or water intrusion around the furnace area. Do not attempt extensive disassembly or wiring repair if you lack the proper training and equipment. Regular maintenance by a licensed HVAC technician is the best way to prevent pressure switch faults.

Prevention And Maintenance

  • Schedule Annual Inspections: A yearly professional check helps identify venting problems, switch wear, and inducer issues before they cause failures.
  • Keep Vents Clean: Regularly inspect and clear PVC vents of obstructions, snow, or debris around exterior vent inlets.
  • Maintain Condensate Drainage: Ensure traps and drains are unobstructed to prevent moisture-related draft problems.
  • Check Tubing For Wear: Periodically inspect pressure switch hoses for cracks and replace as needed.
  • Test CO Detectors: Ensure working alarms on every level of the home and replace batteries as recommended.
  • Use Proper Venting Equipment: Ensure vent pipes, elbows, and joints are correctly installed to maintain proper draft.

Note: The information provided is intended to guide homeowners through non-destructive checks and general understanding. Complex diagnostics or gas-related work should be performed by a licensed HVAC professional to ensure safety and compliance with local codes.